Views: 0 Author: Site Editor Publish Time: 2021-04-19 Origin: Site
The disinfection cabinet that adopts heating and disinfection is energized and heated by an infrared heating tube, and the temperature in the cabinet rises to 200 to 300 degrees Celsius to achieve the purpose of disinfection. The electrodes of the infrared heater tube inside are easily oxidized due to moisture. If the bowl is dripped with water and put into the disinfection cabinet, the electrical components and metal surfaces inside are easily damp and oxidized, and contact resistance appears at the infrared heating tube socket, which is easy to burn the tube socket or other parts and shorten The service life of the disinfection cabinet.
The disinfection cabinet can replace ordinary cupboards and play a cleaning role to avoid secondary pollution of clean dishes. However, although the sealability of the disinfection cupboard is better, if the infrared tube inside does not heat up for a long time, the humid air in the cupboard will be difficult to discharge in time, and the mold attached to the tableware will still breed and endanger human health. Therefore, do not put water-filled tableware in the disinfection cabinet and do not frequently energize. This will cause the electrical components and metal surfaces to be damp and oxidized, and contact resistance is prone to appear at the heating tube socket, which is easy to burn the tube socket or other parts and shorten The service life of the disinfection cabinet. It is best to turn on the disinfection cupboard for disinfection once a day or two, at least once or twice a week, so as to achieve the purpose of disinfection and prolong its service life. The tableware should be washed and drained before being put into the disinfection cupboard for disinfection, which can shorten the disinfection time and reduce the power consumption.
The disinfection cabinet is not a "sacred cabinet" that can eliminate "thousands of poisons". Not everything can be disinfected when put into it, and things including some tableware are not suitable for disinfection with the disinfection cabinet. Different types of tableware should be sterilized separately, that is, the tableware that is not resistant to high temperature can be put into the low temperature sterilization room for sterilization, and the high temperature resistant tableware can be placed in the high temperature sterilization room. Generally speaking, plastic and other tableware that is not resistant to high temperatures cannot be placed in the lower high-temperature disinfection cabinet, but should be disinfected in the upper-level ozone disinfection cabinet to avoid damage to the tableware. Some colorful dishes should not be disinfected in the disinfection cabinet. Because the glazes and pigments of these ceramic dishes contain heavy metals such as lead and cadmium, they will easily overflow if they encounter high temperatures. When the disinfection cabinet is in working condition, the internal temperature can be as high as 200 degrees Celsius. Often placing food in these sterilized colorful porcelains can easily contaminate the food and endanger health. Tableware such as bowls, plates, cups, etc. should be placed vertically on the shelf, preferably not stacked, in order to ventilate and disinfect as soon as possible. Painted utensils should not be sterilized in a high-temperature disinfection cabinet as much as possible, because they contain chemical substances, which are stable at room temperature, but may release harmful substances at high temperatures, which endanger human health.
The disinfection cabinet should be placed in a dry and ventilated place, not less than 30 cm away from the wall. Please do not open the door when it is not necessary during disinfection, so as not to affect the effect. After disinfection, the effect will be better if you take it again after ten minutes.
5. Unless necessary, do not open the cabinet door during the disinfection process, which will affect the disinfection effect and increase power consumption. If it is a high-temperature disinfection cabinet, the temperature in the cabinet is still high after the disinfection is completed, and it usually takes 10 to 20 minutes before the cabinet is opened for retrieval. Every time the disinfection is completed, the power must be turned off in time, or the power plug must be unplugged.